2017-01-18

Task Type: Amélioration

Category: Backbone US

Status: Finished

Nous allons upgrader notre capacité entre mia-5-n7 (Miami, FL, US) et ash-5-n7 (Ashburn, VA, US) en passant de 1x100G à 2x100G.

Cette opération est transparente puisqu'il s'agit d'ajouter le nouveau port 100G dans le bundle LACP entre les 2 POPs.

Comments:

Date: Wed, 18 Jan 2017 09:41:21 +0100

[10:38:42] mia-5-n7 => port-channel1290: Ethernet5/5 is up (%ETH_PORT_CHANNEL-5-PORT_UP)
[10:38:42] mia-5-n7 => Interface port-channel1290,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)

[10:38:42] ash-5-n7 => port-channel1290: Ethernet9/4 is up (%ETH_PORT_CHANNEL-5-PORT_UP)
[10:38:42] ash-5-n7 => Interface port-channel1290,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)

Nous avons désormais 200G de capacité entre Ashburn et Miami !

Nous contrôlons que les services sont ok et qu'il n'y a pas de CRC.

Date: Wed, 18 Jan 2017 09:51:19 +0100

Pas de CRC sur Miami/Ashburn et load balancing ok :

mia-5-n7# sh int eth 5/5, eth 6/4 | i rate|CRC
30 seconds input rate 2774918824 bits/sec, 292392 packets/sec
30 seconds output rate 818157928 bits/sec, 378530 packets/sec
input rate 2.77 Gbps, 292.39 Kpps; output rate 818.16 Mbps, 378.53 Kpps
300 seconds input rate 2858174216 bits/sec, 293595 packets/sec
300 seconds output rate 789085280 bits/sec, 375286 packets/sec
input rate 2.86 Gbps, 293.60 Kpps; output rate 789.09 Mbps, 375.29 Kpps
0 runts 0 giants 0 CRC/FCS 0 no buffer
30 seconds input rate 2446993608 bits/sec, 249818 packets/sec
30 seconds output rate 724936000 bits/sec, 304084 packets/sec
input rate 2.45 Gbps, 249.82 Kpps; output rate 724.94 Mbps, 304.08 Kpps
300 seconds input rate 2519251800 bits/sec, 255626 packets/sec
300 seconds output rate 754568464 bits/sec, 311575 packets/sec
input rate 2.52 Gbps, 255.63 Kpps; output rate 754.57 Mbps, 311.58 Kpps
0 runts 0 giants 0 CRC/FCS 0 no buffer

ash-5-n7# sh int eth 8/4, eth 9/4 | i rate|CRC
30 seconds input rate 660748408 bits/sec, 302388 packets/sec
30 seconds output rate 2462388384 bits/sec, 250073 packets/sec
input rate 660.75 Mbps, 302.39 Kpps; output rate 2.46 Gbps, 250.07 Kpps
300 seconds input rate 731261472 bits/sec, 308892 packets/sec
300 seconds output rate 2499717264 bits/sec, 253836 packets/sec
input rate 731.26 Mbps, 308.89 Kpps; output rate 2.50 Gbps, 253.84 Kpps
0 runts 0 giants 0 CRC/FCS 0 no buffer
30 seconds input rate 784477304 bits/sec, 370637 packets/sec
30 seconds output rate 2883275080 bits/sec, 304489 packets/sec
input rate 784.48 Mbps, 370.64 Kpps; output rate 2.88 Gbps, 304.49 Kpps
300 seconds input rate 784132648 bits/sec, 373379 packets/sec
300 seconds output rate 2839898712 bits/sec, 293564 packets/sec
input rate 784.13 Mbps, 373.38 Kpps; output rate 2.84 Gbps, 293.56 Kpps
0 runts 0 giants 0 CRC/FCS 0 no buffer

Nous clôturons cette tache travaux !

Show more