The Setaflash Series 8 'ActiveCool' is an automated closed cup flash point tester with a temperature range of 10 to 130°C (50 to 266°F) with no external cooling required. When connected to a suitable chilled water supply, the range is extended down to -20°C (-4°F).
There are two modes of operation; Flash / No Flash and Ramp. The ramp mode increases the sample temperature at a rate of 2°C/min and automatically dips the ignitor every 1°C up to 100°C (every 2°C above 100°C), until either a flash is detected or the end of test temperature is reached.
ADDITIONAL INFORMATION
The automatic flash detection system is tuned to ignore halo and other false flash effects, enhancing precision and accuracy. Barometric pressure is measured by an internal barometer, and the correction is automatically applied to the test result.
Peltier cell technology is used for heating and cooling, ensuring precise temperature control and rapid cooldown after a test is completed. The ignitor uses a new electrical hot wire (a gas version is available - 82110-0). The bright colour LCD display shows test parameters and the flash point result. The text and colour of the top line indicates instrument status. All functions are accessed via menus, navigated by the keypad. Up to 64 test results can be stored in memory, each tagged with a sample reference and operator name. Results can be downloaded to a PC or printer via the RS232C port (USB or LAN ports options available). The firmware is upgradeable for future developments.
SUPPLIED WITH: Ignitor, 2ml syringe, mains lead and instruction manual.
SPECIFICATIONS
Description
Temperature Range
Air: 10 to 130°C (50 to 266°F) Water Assisted: -20 to 130°C (-4 to 266°F) using 99300-2
Sample Size
2 or 4ml according to method
Ignitor
Electrical Hot Wire
Test duration, Rapid Equilibrium Mode
1 minute below 100°C, 2 minutes above 100°C, FAME 1 minute or user defined 1 to 99 minutes
Test duration, Ramp Mode
Typically 7 minutes
Cool Down Time
80 to 20°C (176 to 68°F) in 4 minutes
Sample Cup Material
Corrosion resisting steel insert, aluminium cup
Heating / Cooling Method
Peltier Cell
Computer Interface
RS232C (USB & LAN options)
Voltage
100 to 250V, 50/60Hz (2x AA dry cell batteries required for internal clock)
Power
300W (maximum)
Size (HxWxD)
30 x 34 x 38cm
Weight
8kg
CCCN Code:
Tariff 90268020
FEATURES
10°C to 130°C (-20°C with external water supply)
Small sample size, 2 or 4ml
Flash/No Flash & Ramp modes
Electric ignitor
Automatic dipping and flash detection
ActiveCool electronic Peltier cooling
64 Test memory & RS232 interface
°C or °F temperature display
Corrosion resisting insert
METHODS
ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 3900 Part A13, BS 6664 Parts 3 & 4, CHIPS Regulations, EPA 1020 A & B, IP 523, IP 524, IP 534, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids
DETAILS OF METHODS
Method
Description
CHIPS Regulations
Chemicals Hazard Information and Packaging for Supply
EPA 1020 A & B
Setaflash Closed-Cup Method for determining ignitability
ASTM D3828
Standard Test Methods for Flash Point by Small Scale Closed Tester
ASTM D3278
Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - The test methods are applicable to paints, enamels, lacquers, varnishes, and related products having a flash point between 0 and 110°C (32 and 230°F) and Viscosity lower than 150 St at 25°C (77°F).
ISO 3680
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
UN Class 3 Non-viscous Flammable Liquids
Small scale flash point testers are universally specified in many international regulations to define and classify "flammable" and "combustible" substances.
ASTM E502
Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
ISO 3679
Determination of flash point. Rapid equilibrium closed cup method
BS 6664 Parts 3 & 4
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (closed cup equilibrium method)
BS 3900 Part A13
Test for flash/no flash (rapid equilibrium method)
IP 523
Determination of flash point. Rapid equilibrium closed cup method
IP 524
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM D7236
Flash Point by Small Scale Closed Cup Ramp Method
IP 534
Flash Point by Small Scale Closed Cup Ramp Method