电力VC降级经过程
10月28号接到电力VC降级的case,去之前查阅了两种降级方式,第一种是HPSUM,另一个是vcsu方式,到达现场后发现HPSUM这种方式能把OA和其他的firmware可以降下来,但是VC模块的版本降级不成功,就改用VCSU方式降级,降级方式如下:
vcsu -a update -i 192.168.0.1 -u Administrator -p HWGYDAC7 -vcu Administrator -vcp Z66BT2RX -l D:\vcfwall410.bin
OAIP OA用户 OA密码 VC用户 VC密码 fw路径
第一台降级成功后第二台用同样方式进行降级时,一直报错找不到bay设备,在OA下敲入connect bay 命令时报错如下:
-----------------------------------------------------------------------------
WARNING: This is a private system. Do not attempt to login unless you are an
authorized user. Any authorized or unauthorized access and use may be moni-
tored and can result in criminal or civil prosecution under applicable law.
-----------------------------------------------------------------------------
Firmware Version: 4.30
Built: 07/08/2014 @ 16:13
OA Bay Number: 2
OA Role: Active
HP BladeSystem Onboard Administrator
(C) Copyright 2006-2014 Hewlett-Packard Development Company, L.P.
Type 'HELP' to display a list of valid commands.
Type 'HELP <command>' to display detailed information about a specific command.
Type 'HELP HELP' to display more detailed information about the help system.
C3000-1> connect bay 3
Connecting to bay 3 ...
Maximum CLI sessions currently open.
Please close an open session and try again.
RC给的解决方案是:
CM:hpiLO-> sa
SA
This command allows you to modify MP access configuration.
Current Set Access Configuration:
T - Telnet : Enabled
W - Web SSL : Enabled
H - SSH : Disabled
Enter parameter(s) to change, A to modify All, or [Q] to Quit: h
h
For each parameter, enter:
New value, or
<CR> to retain the current value, or
DEFAULT to set the default value, or
Q to Quit
SSH Access Configuration:
Current -> D - Disabled
E - Enabled (default)
Enter new value, or Q to Quit: e
e
-> SSH Port Access Configuration will be updated
New Set Access Configuration (* modified values):
T - Telnet : Enabled
W - Web SSL : Enabled
* H - SSH : Enabled
Enter Parameter(s) to revise, Y to confirm, or [Q] to Quit: y
y
但是第一天连接MP时也不成功,然后进行bay的掉电试MP卡重置,还是报错,由于客户下班原因就准备将报错日志拷下来进行再降级,今天到达现场进行MP掉电重置时发现可以连接MP成功,就按照RC的解决办法进行SSH的enabled操作,操作完成后在OA里进行connect bay操作可以成功,就按照VCSU方法进行降级,当降级进行到第二步时报错出现:
[Thu Oct 30 14:51:37 2014] Starting firmware update process
[Thu Oct 30 14:51:40 2014] Updating firmware [Step 2 of 3 : 0% complete]
[Thu Oct 30 14:51:55 2014] Activating firmware [Step 3 of 3 : 5% complete]
[Thu Oct 30 14:52:05 2014] Firmware update completed
[Thu Oct 30 14:52:05 2014] The following modules were not attempted:
[Thu Oct 30 14:52:05 2014]
[Thu Oct 30 14:52:05 2014] ==========================================================
[Thu Oct 30 14:52:05 2014] Enclosure Bay Module Status
[Thu Oct 30 14:52:05 2014] ==========================================================
[Thu Oct 30 14:52:05 2014] SGH428LFTX 1 HP VC Flex-10/10D Module Not Attempted
[Thu Oct 30 14:52:05 2014]
[Thu Oct 30 14:52:05 2014] Total execution time: 00:02:12
[Thu Oct 30 14:52:05 2014]
[Thu Oct 30 14:52:05 2014] VCSU log file is available at the following location: C:\Program Files
[Thu Oct 30 14:52:05 2014] (x86)\Hewlett-Packard Company\Virtual Connect Support Utility\vcsu-5992.log
再次请求RC支持给的方案是将VC模块重置,重置后发现还是不行,报错一样,在各种方法试遍之后,我将设备的HP VC 8Gb 20-Port FC Module模块从2槽位移到3槽位进行降级操作,降级成功,成功将两台设备的VC模块降级到4.1。